You can support the authors in the further development of the project.
Buy us a coffee at buymeacoffee.com Donate with PayPal button

Move configuration from the old GUI-Generic

How to move the configuration

The converter turns an old GUI-Generic configuration file (.dat) into a backup for the new GUI-Generic built here (.tar). It moves WiFi, Supla server settings, GUID and AUTHKEY, the panel login, and inputs and outputs with the same channel numbers, so Supla Cloud keeps the same device.

  1. In the old GUI-Generic open Tools and click “Save configuration” — a .dat file will be downloaded.
  2. Select that file below, check the channel list and download the .tar file.
  3. Build the new GUI-Generic here with the “Configuration backup” option (enabled by default) and flash it to the same device.
  4. Connect to the device WiFi network, open Tools → Backup / Restore, select the .tar file and click Restore. The device restarts with the moved configuration.

Before flashing the new GUI-Generic, keep a way back. The safest is a copy of the whole device flash over USB (esptool read_flash) — it contains the old firmware together with its configuration and can be flashed back unchanged. Also keep the .dat file: after flashing the old GUI-Generic (e.g. rebuilt in the old builder) restore it in Tools → “Load configuration”.

Important: when building, choose the same FLASH size as the device has (e.g. ESP-01 usually has 1 MB, ESP-12 modules 4 MB). Firmware built for a larger flash will upload, but will not start the panel or save the configuration.

The file is read only in your browser — it is not sent to the server.

Old GUI-Generic configuration file (.dat)